Steven Reilly, Senior Consultant – Fire and Life Safety at Dubai Airports, asks what constitutes an effective response?
Emergency response planning from a fire and life-safety point of view is generally considered to be limited to the provision of designing compliant Emergency Vehicle Access (EVA).
However, at the heart of every fire and life safety strategy is the dependence on a local fire service to respond to the fire incident in a reasonable amount of time to mitigate the situation before it grows out of control.
In other words, a fire strategy is not limited to only looking at how much of the building perimeter an emergency response vehicle can park near.
Firefighting and civilian rescue are far more than a big red truck squirting water at the side of a building, as we’ve seen in the movies.
Detection systems are installed to detect the fire; alarm systems alert building occupants and fire sprinkler systems prevent fire from developing to the flashover stage, where all contents of a room violently ignite simultaneously.
The general consensus is that fire sprinklers fully extinguish a fire 90% of the time, which leaves 10% of fires requiring a fire service intervention.
Then there are also a significant number of buildings that are not protected with fire sprinklers.
Therefore, it is imperative that trained and equipped firefighting personnel reach the incident as early as possible.
The ability to swiftly and effectively deploy a fully equipped response force can mean the difference between containment of a fire incident and catastrophe; every second counts.
Industry standards
Recognising this critical need, the National Fire Protection Association (NFPA), in collaboration with industry professionals, has developed the NFPA 1710 – Standard for the Organisation and Deployment of Fire Suppression Operations, Emergency Medical Operations and Special Operations to the Public by Career Fire Departments, which provides a benchmark for fire department performance, focusing on response times, personnel deployment and operational efficiency.
This standard serves as a guiding principle for fire departments in the United States and internationally, aiming to optimise emergency response capabilities and ensure the safety of both firefighters and the public.
Firstly, NFPA 1710 sets the standard for the maximum amount of time allowed for career firefighters to arrive at a fire incident, from the time the initial emergency call is received at the dispatch centre, to arrival on the scene and initiate action, this is referred to as the Total Response Time.
The standard identifies four minutes as the benchmark for fire engine arrival travel time 90% of the time.
The clock stops upon the arrival of an “NFPA 1901- Standard for Automotive Fire Apparatus” compliant fire engine containing all required tools and equipment, including a minimum 750 GPM pump (but preferred 1000- or 1500 GMP where possible).
Occasionally, projects recommend a modified golf buggy, a converted pickup or even a motorcycle.
While this apparatus may be acceptable for a rubbish fire or a medical incident, they do not meet the NFPA 1901 requirements for a structure fire pumper.
The four-minute response time may seem overly ambitious and subject to outside factors such as traffic, narrow streets or poorly located fire stations; however, it should be considered when master planning fire station locations.
Effective response time
At the heart of NFPA 1710 lies the concept of the Effective Response Force (ERF). This refers to the minimum number of personnel and equipment required to initiate an effective fire attack and rescue operation.
The ERF is determined by conducting a comprehensive Critical Task Analysis (CTR), which involves analysing incident scenarios, assessing potential hazards and formulating operational strategies that optimise resource allocation and response efficiency to deal with the potential worst-case scenario incidents in the area served by the fire service.
When possible, an individual analysis may be calculated for each building based on risk.
However, NFPA 1710 outlines the minimum number of firefighters to establish the ERF for typical buildings.
Considering a typical emergency response vehicle can carry up to 4-6 firefighters, this would mean that for a typical high-rise building (over 23m), at least nine emergency response vehicles would be expected to respond to meet the NFPA 1710 ERF.
I don’t believe this is something that inexperienced fire and life safety consultants consider when developing fire strategies for such buildings.
This does not mean that nine fire vehicles will be used for firefighting pumping activities.
It has more to do with the number of firefighters and equipment required at the scene of operations.
It is imperative to recognise that fire service operations are based upon standard operating procedures that identify different roles and responsibilities for a variety of staff.
One of the most important aspects of this is command and control, planning and revisiting plans and communications.
Without these in place at major incidents, the safety of firefighters cannot be guaranteed.